Product Number: PCIe
Serial Number:
Description:
User Name: Unknown User
User's Comment:
Software Version:
PCI Express N5990A ValiFrame3.5.4.1
Test nameResult
L0_Cal_16GTps_PSPassed
L0_Cal_16GTps_DEPassed
L0_Cal_16GTps_VdiffPassed
L0_Cal_16GTps_RJPassed
L0_Cal_16GTps_LFSJPassed
L0_Cal_16GTps_HFSJPassed
L0_Cal_16GTps_UIPassed
L0_Cal_16GTps_ILPassed
L0_Cal_16GTps_DMSIPassed
L0_Cal_16GTps_CMSIPassed
L0_Cal_16GTps_IniPres_EHPassed
L0_Cal_16GTps_IniPres_EWPassed
L0_Cal_16GTps_Chan_EHPassed
L0_Cal_16GTps_Chan_EWPassed
L0_Cal_16GTps_FinPres_EHPassed
L0_Cal_16GTps_FinPres_EWPassed
L0_Cal_16GTps_PreCompPassed
L0_Cal_16GTps_CompEyePassed
L0_EqRx_16GTps_CompFailed

CompanyInstrument NameSerialInstrument RevisionDescription
Keysight TechnologiesM8070BMY577021228.0.280.26M8020 with integrated jitter sources for BER tests
Keysight TechnologiesDSO Infiniium SeriesUnknownUnknownRealtime scope for stress signal calibration

----General----
OfflineFalse
EQ Calibration PatternEQ Two Pattern, 64 zeros, 64 ones
Verification ModeFalse
Start With Minimum Loss ChannelFalse
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth32 GHz
Number of Waveform Averages256
Scope Connection for CalibrationChan 1 3 Direct Connect
----​​​Generator----
Set Amplitude800 mV
Set Pre-Shoot [dB]DE (-6 dB) [dB]DE (-5 dB) [dB]DE (-4 dB) [dB]DE (-3 dB) [dB]DE (-2 dB) [dB]DE (-1 dB) [dB]DE (0 dB) [dB]
0.000.390.370.320.290.260.240.22
1.001.371.331.271.341.271.221.19
2.002.442.422.412.362.302.292.24
3.003.453.423.443.443.393.293.25
4.004.564.484.494.454.414.404.31
5.005.625.675.495.485.495.425.34
6.006.626.616.626.586.596.496.45

----General----
OfflineFalse
EQ Calibration PatternEQ Two Pattern, 64 zeros, 64 ones
Verification ModeFalse
Start With Minimum Loss ChannelFalse
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth32 GHz
Number of Waveform Averages256
Scope Connection for CalibrationChan 1 3 Direct Connect
----​​​Generator----
Set Amplitude800 mV
Set De-Emphasis [dB]PS (0 dB) [dB]PS (1 dB) [dB]PS (2 dB) [dB]PS (3 dB) [dB]PS (4 dB) [dB]PS (5 dB) [dB]PS (6 dB) [dB]
-6.00-6.55-6.75-6.82-6.92-7.21-7.44-7.63
-5.00-5.54-5.64-5.89-6.06-6.26-6.62-6.83
-4.00-4.57-4.75-4.98-5.24-5.53-5.63-5.89
-3.00-3.56-3.80-4.10-4.40-4.54-4.78-5.09
-2.00-2.59-2.84-3.11-3.36-3.56-3.79-4.12
-1.00-1.58-1.94-2.16-2.46-2.72-2.96-3.22
0.00-0.50-0.87-1.18-1.39-1.67-1.94-2.24

----General----
OfflineFalse
EQ Calibration PatternEQ Two Pattern, 64 zeros, 64 ones
Verification ModeFalse
Start With Minimum Loss ChannelFalse
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth32 GHz
Number of Waveform Averages256
Scope Connection for CalibrationChan 1 3 Direct Connect
----​​​Generator----
Set Amplitude800 mV
Set Pre-Shoot [dB]DE (-6 dB) [mV]DE (-5 dB) [mV]DE (-4 dB) [mV]DE (-3 dB) [mV]DE (-2 dB) [mV]DE (-1 dB) [mV]DE (0 dB) [mV]
0.00929.00923.00930.00924.00925.00926.00925.00
1.00919.00920.00922.00926.00926.00922.00923.00
2.00923.00923.00922.00921.00921.00924.00929.00
3.00919.00923.00925.00924.00920.00921.00922.00
4.00920.00923.00921.00923.00926.00926.00926.00
5.00918.00924.00926.00922.00922.00926.00922.00
6.00922.00925.00919.00921.00924.00922.00925.00

----General----
OfflineFalse
Verification ModeFalse
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages3
Number of UIs2 MUI
Scope Connection for CalibrationChan 1 3 Direct Connect
----​​​Generator----
Pre-Shoot0 dB
De-Emphasis0 dB
Generator Voltage800 mV
Set Random Jitter [ps]Measured Random Jitter [ps]
0.000.31
0.250.40
0.500.59
0.750.82
1.001.06
1.501.55
2.002.05
3.003.07
4.004.11

----General----
OfflineFalse
Verification ModeFalse
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages3
Number of UIs2 MUI
Scope Connection for CalibrationChan 1 3 Direct Connect
----​​​Generator----
Pre-Shoot0 dB
De-Emphasis0 dB
Generator Voltage800 mV
Set SJ [ps]SJ (0.2 MHz) [ps]SJ (0.5 MHz) [ps]SJ (1 MHz) [ps]SJ (2 MHz) [ps]SJ (4 MHz) [ps]
6.256.256.206.126.086.09
12.5012.5011.9611.9311.9612.01
25.0023.9224.3124.3624.2924.26
50.0047.8249.7049.4049.3249.21
100.0096.3999.3298.9599.0799.13
200.00193.27198.74199.23198.57198.96

----General----
OfflineFalse
Verification ModeFalse
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages3
Number of UIs2 MUI
Scope Connection for CalibrationChan 1 3 Direct Connect
----​​​Generator----
Pre-Shoot0 dB
De-Emphasis0 dB
Generator Voltage800 mV
Set SJ [ps]SJ (5 MHz) [ps]SJ (10 MHz) [ps]SJ (100 MHz) [ps]
0.000.000.000.00
6.255.605.585.59
12.5011.5411.5811.92
18.7518.0718.0118.18
25.0024.5224.5724.54

----General----
OfflineFalse
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages7
Number of UIs2 MUI
Scope Connection for CalibrationChan 1 3 Direct Connect
----​​​Generator----
Pre-Shoot0 dB
De-Emphasis0 dB
Generator Voltage800 mV
Mean Unit Interval [ps]
62.500092973

----General----
OfflineFalse
Measurement MethodVNA (manual)
Trace Loss Increment-0.5 dB
Save Calibration DataTrue
Start With Minimum Loss ChannelFalse
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages7
Number of Waveform Averages1024
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Variable ISI pairs----
CBB var. ISI pair11
CLB var. ISI pair -27dB Channel1
CLB var. ISI pair -28dB Channel1
CLB var. ISI pair -30dB Channel3
Frequency [GHz]Insertion Loss (Trace 1) [dB]Insertion Loss (Trace 2) [dB]Insertion Loss (Trace 3) [dB]
1.00-4.70-4.95-5.20
1.10-5.03-5.29-5.55
1.20-5.37-5.64-5.91
1.30-5.70-5.98-6.26
1.40-6.03-6.32-6.62
1.50-6.36-6.67-6.97
1.60-6.70-7.01-7.33
1.70-7.03-7.36-7.68
1.80-7.36-7.70-8.03
1.90-7.70-8.04-8.39
2.00-8.03-8.39-8.74
2.10-8.36-8.73-9.10
2.20-8.69-9.07-9.45
2.30-9.03-9.42-9.81
2.40-9.36-9.76-10.16
2.50-9.69-10.10-10.51
2.60-10.03-10.45-10.87
2.70-10.36-10.79-11.22
2.80-10.69-11.13-11.58
2.90-11.02-11.48-11.93
3.00-11.36-11.82-12.29
3.10-11.69-12.17-12.64
3.20-12.02-12.51-12.99
3.30-12.36-12.85-13.35
3.40-12.69-13.20-13.70
3.50-13.02-13.54-14.06
3.60-13.35-13.88-14.41
3.70-13.69-14.23-14.77
3.80-14.02-14.57-15.12
3.90-14.35-14.91-15.47
4.00-14.69-15.26-15.83
4.10-15.02-15.60-16.18
4.20-15.35-15.94-16.54
4.30-15.68-16.29-16.89
4.40-16.02-16.63-17.25
4.50-16.35-16.98-17.60
4.60-16.68-17.32-17.95
4.70-17.02-17.66-18.31
4.80-17.35-18.01-18.66
4.90-17.68-18.35-19.02
5.00-18.01-18.69-19.37
5.10-18.35-19.04-19.73
5.20-18.68-19.38-20.08
5.30-19.01-19.72-20.43
5.40-19.35-20.07-20.79
5.50-19.68-20.41-21.14
5.60-20.01-20.75-21.50
5.70-20.34-21.10-21.85
5.80-20.68-21.44-22.21
5.90-21.01-21.79-22.56
6.00-21.34-22.13-22.91
6.10-21.68-22.47-23.27
6.20-22.01-22.82-23.62
6.30-22.34-23.16-23.98
6.40-22.67-23.50-24.33
6.50-23.01-23.85-24.69
6.60-23.34-24.19-25.04
6.70-23.67-24.53-25.39
6.80-24.01-24.88-25.75
6.90-24.34-25.22-26.10
7.00-24.67-25.56-26.46
7.10-25.00-25.91-26.81
7.20-25.34-26.25-27.17
7.30-25.67-26.60-27.52
7.40-26.00-26.94-27.87
7.50-26.34-27.28-28.23
7.60-26.67-27.63-28.58
7.70-27.00-27.97-28.94
7.80-27.33-28.31-29.29
7.90-27.67-28.66-29.65
8.00-28.00-29.00-30.00

----General----
OfflineFalse
Verification ModeFalse
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Waveform Averages128
Horizontal Range40 ns
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Channel----
CLB var. ISI pair1
CBB var. ISI pair11
Total Channel Loss-28 dB
Set DMSI [mV]Measured DMSI [mV]
0.000.17
5.004.06
10.009.65
15.0014.56
20.0019.46
30.0029.28
40.0039.10
50.0048.93

----General----
OfflineFalse
Verification ModeFalse
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Waveform Averages128
Number of UIs2 MUI
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Channel----
CLB var. ISI pair1
Total Channel Loss-28 dB
Set CMSI [mV]Measured CMSI [mV]
0.000.11
100.0047.93
200.0096.49
300.00144.05
400.00191.50
500.00241.79
600.00293.39

----General----
OfflineFalse
Equalization Preset RangeP5;P6
CTLE Start Value-9.75 dB
CTLE Stop Value-8.75 dB
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages7
Number of UIs2 MUI
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Channel----
CLB var. ISI pair3
CBB var. ISI pair11
Total Channel Loss-30 dB
----​​​Generator----
Generator Launch Voltage800 mV
DMSI14 mV
Random Jitter1 ps
Sinusoidal Jitter6.25 ps
Sinusoidal Jitter Frequency100 MHz
Set Equalization Preset []Measured Eye Height (-9.75 dB CTLE) [mV]Measured Eye Height (-9.5 dB CTLE) [mV]Measured Eye Height (-9.25 dB CTLE) [mV]Measured Eye Height (-9 dB CTLE) [mV]Measured Eye Height (-8.75 dB CTLE) [mV]
5.0012.8116.1016.3017.2018.43
6.0014.2213.1319.0019.0418.65

----General----
OfflineFalse
Equalization Preset RangeP5;P6
CTLE Start Value-9.75 dB
CTLE Stop Value-8.75 dB
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages7
Number of UIs2 MUI
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Channel----
CLB var. ISI pair3
CBB var. ISI pair11
Total Channel Loss-30 dB
----​​​Generator----
Generator Launch Voltage800 mV
DMSI14 mV
Random Jitter1 ps
Sinusoidal Jitter6.25 ps
Sinusoidal Jitter Frequency100 MHz
Set Equalization Preset []Measured Eye Width (-9.75 dB CTLE) [ps]Measured Eye Width (-9.5 dB CTLE) [ps]Measured Eye Width (-9.25 dB CTLE) [ps]Measured Eye Width (-9 dB CTLE) [ps]Measured Eye Width (-8.75 dB CTLE) [ps]
5.0018.7420.3221.0022.6323.63
6.0018.6619.5021.5721.8523.27

----General----
OfflineFalse
Trace Number Start Value3
Trace Number Stop Value0
CTLE Start Value-9.75 dB
CTLE Stop Value-8.75 dB
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages7
Number of UIs2 MUI
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Channel----
CBB var. ISI pair11
----​​​Generator----
Pre-Shoot1.9 dB
De-Emphasis0 dB
Generator Launch Voltage800 mV
DMSI14 mV
Random Jitter1 ps
Sinusoidal Jitter6.25 ps
Sinusoidal Jitter Frequency100 MHz
Set CLB var. ISI pair []Measured Eye Height (-9.75 dB CTLE) [mV]Measured Eye Height (-9.5 dB CTLE) [mV]Measured Eye Height (-9.25 dB CTLE) [mV]Measured Eye Height (-9 dB CTLE) [mV]Measured Eye Height (-8.75 dB CTLE) [mV]
3.0012.8116.1016.3017.2018.43

----General----
OfflineFalse
Trace Number Start Value3
Trace Number Stop Value0
CTLE Start Value-9.75 dB
CTLE Stop Value-8.75 dB
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages7
Number of UIs2 MUI
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Channel----
CBB var. ISI pair11
----​​​Generator----
Pre-Shoot1.9 dB
De-Emphasis0 dB
Generator Launch Voltage800 mV
DMSI14 mV
Random Jitter1 ps
Sinusoidal Jitter6.25 ps
Sinusoidal Jitter Frequency100 MHz
Set CLB var. ISI pair []Measured Eye Width (-9.75 dB CTLE) [ps]Measured Eye Width (-9.5 dB CTLE) [ps]Measured Eye Width (-9.25 dB CTLE) [ps]Measured Eye Width (-9 dB CTLE) [ps]Measured Eye Width (-8.75 dB CTLE) [ps]
3.0018.7420.3221.0022.6323.63

----General----
OfflineFalse
Equalization Preset RangeP5;P6
CTLE Start Value-9.75 dB
CTLE Stop Value-8.75 dB
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages7
Number of UIs2 MUI
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Channel----
CLB var. ISI pair3
CBB var. ISI pair11
Total Channel Loss-30 dB
----​​​Generator----
Generator Launch Voltage800 mV
DMSI14 mV
Random Jitter1 ps
Sinusoidal Jitter6.25 ps
Sinusoidal Jitter Frequency100 MHz
Set Equalization Preset []Measured Eye Height (-9.75 dB CTLE) [mV]Measured Eye Height (-9.5 dB CTLE) [mV]Measured Eye Height (-9.25 dB CTLE) [mV]Measured Eye Height (-9 dB CTLE) [mV]Measured Eye Height (-8.75 dB CTLE) [mV]
5.0013.2615.0217.7118.8919.70
6.0013.9113.3119.2816.4220.43

----General----
OfflineFalse
Equalization Preset RangeP5;P6
CTLE Start Value-9.75 dB
CTLE Stop Value-8.75 dB
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages7
Number of UIs2 MUI
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Channel----
CLB var. ISI pair3
CBB var. ISI pair11
Total Channel Loss-30 dB
----​​​Generator----
Generator Launch Voltage800 mV
DMSI14 mV
Random Jitter1 ps
Sinusoidal Jitter6.25 ps
Sinusoidal Jitter Frequency100 MHz
Set Equalization Preset []Measured Eye Width (-9.75 dB CTLE) [ps]Measured Eye Width (-9.5 dB CTLE) [ps]Measured Eye Width (-9.25 dB CTLE) [ps]Measured Eye Width (-9 dB CTLE) [ps]Measured Eye Width (-8.75 dB CTLE) [ps]
5.0018.9020.0021.4122.9023.04
6.0018.5720.5421.0022.6022.87

----General----
OfflineFalse
CTLE-8.75 dB
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages21
Number of UIs2 MUI
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Channel----
CLB var. ISI pair3
CBB var. ISI pair11
Total Channel Loss-30 dB
----​​​Generator----
Pre-Shoot2.5 dB
De-Emphasis0 dB
Random Jitter1 ps
DMSI [mV]SJ [ps]Vdiff [mV]Eye Height [mV]Eye Width [ps]
14.06.2580020.8123.40
25.06.2580013.1918.76
14.010.0080014.5919.32
14.06.2572015.7821.26

----General----
OfflineFalse
CTLE-8.75 dB
Start With Minimum Loss ChannelFalse
SigTest Version4.0.52
OscilloscopeKeysight DSO, DSAV334A, SN: MY57500102, FW rev.: 06.60.00601, Used for Calibration
BERT SystemKeysight M8020A J-BERT, M8070B, SN: MY57702122
Generator Channel ChannelM1.DataOut1
----​​Oscilloscope----
Scope Bandwidth25 GHz
Number of Averages21
Number of UIs2 MUI
Gen4 Transfer Function File for Package Model on ScopePCIe4RxPackageModel_RootComplex_v2.tf4
Scope Connection for CalibrationChan 1 3 Direct Connect
----Channel----
CLB var. ISI pair3
CBB var. ISI pair11
Total Channel Loss-30 dB
----​​​Generator----
Pre-Shoot2.5 dB
De-Emphasis0 dB
Sinusoidal Jitter Frequency100 MHz
Random Jitter1 ps
----Search Algorithm----
Minimum Vdiff720 mV
Maximum DMSI25 mV
Maximum SJ10 ps
Max Number of Search Steps7
Use nominal EH/EW results from Pre Comp CalTrue
DMSI [mV]SJ [ps]Vdiff [mV]Eye Height [mV]Eye Width [ps]
15.29.8580014.6718.84

----General----
OfflineFalse
BER ModeFixedTime
BER Measurement Duration62.5 s
Allowed Bit Error1
Pause before Auto-AlignFalse
----Channel----
CLB var. ISI pair3
Total Channel Loss-30 dB
----​​​Impairments----
Residual SSC0 s
Random Jitter1 ps
Sinusoidal Jitter9.85 ps
Sinusoidal Jitter Frequency100 MHz
Common Mode Sinusoidal Interference150 mV
Differential Mode Sinusoidal Interference15.2 mV
Generator Launch Voltage800 mV
----Link Training----
Enable Impairments for Loopback TrainingTrue
----​​​​​​​​​​​​​​​​​Loopback Training----
Interactive Training Script File C:\ProgramData\BitifEye\ValiFrameK0\PCIe\Settings\TrainingScripts\Pcie4_16G_M8020A_ILT_Loopback.txt
Default Link Training Lane Number for every LaneAuto
Suppress Loopback Training MessagesFalse
----​​​​​​​​​​​​​​​​Interactive Link Training----
Generator Full Swing24
DUT Target PresetP7
DUT Target Preset Gen4P7
Speed Change ControlBERT
Drop Link MethodLTSSM
----​​​​​​​​​​​​​​​Error Detector----
Use CDRTrue
CDR Loop Bandwidth20 MHz
Peaking1 dB
Analyzer Equalization-9 dB
SensitivityHigh
PolarityNormal
----​​​​BER Measurement----
Relax Time3 s
ResultSinusoidal Jitter Frequency [MHz]Sinusoidal Jitter [ps]Final Generator PresetFinal Generator Pre-shoot [dB]Final Generator De-emphasis [dB]Allowed Bit Errors []Measured Bit Errors []
*** FAIL ***100.09.85P20.0-4.41244